SaphyRAD probes
A wide range of radiation contamination probes are compatible with the SaphyRAD to perform detection and measurement of alpha & beta radiations.
Bertin instruments has developed a wide range of external probes dedicated to the SaphyRAD contamination monitor. These smart probes allow for the assessment of small or large-area inspection to detect alpha, beta or alpha & beta radioactive contamination. The probes’ design is ergonomic and user friendly to ensure the workers’ safety. The beta probe for small-area detection includes an embedded contamination alarm monitor and a proximity sensor for an efficient and fast control. A floor stand allows the installation of a mobile checkpoint for clearance control.
SaphyRAD, universal contamination meter with improved ergonomics
Julien Villert, Bertin’s Health Physics Product Manager, explains how the innovative probes of the SaphyRAD radiation contamination meter have been enhanced. Designed for EDF, this instrument has been enriched to suit the needs not only of the nuclear market, but also nuclear medicine, research and industry. Thanks to its alarm and distance control indicators, and its configurable radionuclide library, it is easy to use in all fields requiring radiation contamination detection, even by non specialists.
Get a quote for
SaphyRAD probes
Characteristics of the probes
Characteristics of the probes
Type of detection: 1 channel for α,β (Global counting)
Proximity sensor: YES
Radiation alarm: YES
Type of detector: Double Geiger-Müller (GM) Pancake
Surface of detector: 31 cm²
Sensitivity: 0.21 c/s/Bq (36Cl)
Measuring range: 0.1 to 2,150 Bq/cm²
Energy range: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 124x74x190 mm
Weight: 630g
Characteristics of the probes
Type of detection: 1 channel for α,β (Global counting)
Proximity sensor: YES
Radiation alarm: YES
Type of detector: Thin plastic scintillator
Surface of detector: 100 cm²
Sensitivity: 0.29 c/s/Bq (36Cl)
Measuring range: 0.1 to 1,000 Bq/cm²
Energy range: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 293x119x121 mm
Weight: 600g
Characteristics of the probes
Type of detection: 2 measurement channels : 1 for α, 1 for β
Proximity sensor: YES
Radiation alarm: YES
Type of detector: ZnS + thin plastic scintillator
Surface of detector: 100 cm²
Sensitivity:
• α: 0.14 c/s/Bq (241Am)
• β: 0.23 c/s/Bq (36Cl)
Measuring range:
• α: 0.01 to 100 Bq/cm²
• β: 0.1 to 1,000 Bq/cm²
Energy range:
• α: 3 MeV to 8 MeV
• β: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 293x119x121 mm
Weight: 600g
Characteristics of the probes
Type of detection: 1 channel for α,β (Global counting)
Proximity sensor: YES
Radiation alarm: YES
Type of detector: Thin plastic scintillator
Surface of detector: 170 cm²
Sensitivity: 0.29 c/s/Bq (36Cl)
Measuring range: 0.1 to 1,000 Bq/cm²
Energy range: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 308x143x128 mm
Weight: 740g
Characteristics of the probes
Type of detection: 2 measurement channels : 1 for α, 1 for β
Proximity sensor: YES
Radiation alarm: YES
Type of detector: ZnS + thin plastic scintillator
Surface of detector: 170 cm²
Sensitivity:
• α: 0.15 c/s/Bq (241Am)
• β: 0.25 c/s/Bq (36Cl)
Measuring range:
• α: 0.01 to 100 Bq/cm²
• β: 0.1 to 1,000 Bq/cm²
Energy range:
• α: 3 MeV to 8 MeV
• β: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 308x143x128 mm
Weight: 740g
Characteristics of the probes
Type of detection: 2 measurement channels : 1 for α, 1 for β and γ
Proximity sensor: YES
Radiation alarm: YES
Type of detector: ZnS + thick plastic scintillator
Surface of detector: 170 cm²
Sensitivity:
• α: 0.16 c/s/Bq (241Am)
• β: 0.28 c/s/Bq (36Cl)
Measuring range:
• α: 0.01 to 100 Bq/cm²
• β: 0.1 to 1,000 Bq/cm²
Energy range:
• α: 3 MeV to 8 MeV
• β: 100 KeV to 2.2 MeV
Dimensions (L x W x H): 308x143x128 mm
Weight: 740g